Wiki Page: How do I change the PDCE collection interval when using SAM to Monitor servers?

$
0
0
In Performance Explorer, the setting that governs the PDCE collection interval is the TSD-Writer interval (1sec to 60 minutes). To ensure a Data source will be monitored using the TSD-Writer interval you have selected, this option must be set BEFORE the Data Source is configured, and the Monitor will subsequently adhere to your previously selected interval. However, the TSD-Writer interval can be changed during the Monitoring period. If the Data Source has been added and the Monitoring period has begun, you can change the TSD-Writer Interval (PDCE collection Interval) by using the following procedure ONLY: Select New Monitor Report. This cannot be done for a Monitor Graph. "Drag and Drop" the System measures from the Monitor pane into the New Monitor Report Right click on the "Interval" setting Select PROPERTIES | TSD-WRITER tab | Change to new interval of your choice | OK The new PDCE collection Interval will continue throughout the remaining Monitoring Period. NOTE: The SETTINGS | OPTIONS | MONITOR tab | Interval will only effect the interval at which the graph will be updated.  