Wiki Page: Performance Explorer displays "PDCE 2 Data collection did not finish at a given interval" during monitoring?

$
0
0
PDCE is the Performance Data Collection Engine. The Data Collection Interval is the frequency at which the the Data Collection Engine makes requests for monitoring data. This error is caused when the request for monitoring data made from the controller takes longer than the specified Data Collection interval time.  The most common cause for this is using relatively short Data Collection Intervals, for example, 1 second, when the machine being monitored is under stress and therefore cannot respond to the request quickly enough. The solution for this is to increase the Data Collection Interval.  To do this open Performance Explorer and select SETTINGS | OPTIONS | MONITOR TAB | INTERVAL TIME. Old KB# 19463