Wiki Page: Why is an overview report not generated after my load test completes?

$
0
0
Why is an overview report not generated after my load test completes? After a load test has been completed and you click on "Explore Results" and then "Display your results in easy-to-see graphical form by using the Silk Performance Explorer", the overview report should then be automatically created and displayed. However there is a known issue with SilkPerformer 2006R2 where the overview report will not be automatically created if "detailed page timers" are enabled. This setting can be found: SETTINGS | ACTIVE PROFILE | REPLAY | RESULTS | TIME SERIES The "detailed page timers" are disabled by default. To workaround this known issue you should disable "detailed page timers" as shown above and run the test again. Note that a merged TSD file (m@xxx.tsd) is not created when detailed page timers are enabled, it may be possible to merge the individual TSD files manually. This issue only affects SilkPerformer 2006R2 and will be fixed in SilkPerformer 2007. Old KB# 17076