Wiki Page: Silk Performer does not record Rumba AS400 sessions.

$
0
0
When trying to record Rumba with Silk Performer, no functions are recorded and the AS400 session does not connect to the Mainframe server. The Silk Performer recorder log also shows entries such as: WinSockCall(#580, connect) {   connecting to 127.0.0.1:6860   redirecting to 10.111.13.40:19180 } SocksConnect (0) To resolve this problem, go to Settings | System | Recorder | Application Profiles and locate the profile for the AS400 session. In Rumba 9.2 this is tn525032.exe. Open the Web Settings option and check the option to 'Exclude local traffic' Click OK to close the windows and try recording again. Depending on the AS400 session, it might be necessary to restart Rumba before trying another recording.